• How can we help?
  • +91-120-2776277
  • sales@millp.co.in
    MIMIMIMI
    • Home
    • Electrical Metrology Products and Standards
      • Resistance standards
        • Quantam Hall Standards
          • 6800A QHR Turnkey System
          • 6800B QHR Turnkey System with Helium re-liquefaction
        • Standard Resistors
        • Precision High Current Resistors/Shunts
          • 9332 Series High Current Resistors
        • Temperature Stabalized Resistance Standards
          • 4304 Four Element – Travelling Standard
          • 4310HR High Value Six Elements
          • 4310 Five – Ten Elements
        • Resistance Measurement Bridges
          • MODEL 6020Q QUANT Ω Bridge
          • 6000B (10 kΩ to 1 GΩ)
          • 6600A (10 MΩ to 10 PΩ)
          • 6010D (0.01 Ω to 100 kΩ)
          • 6242D (0.001Ω to 1GΩ)
        • High Resistance Meters
          • 6650AF (1 MΩ to 100 TΩ)
        • Scanners and Extenders
          • 42XXA Series of Four Terminal Scanners
          • 42XXB Series of Four Terminal Scanners
          • 46XX Series of High Resistance Scanners
          • 6011 Series of Range Extenders
          • 6023, 6024, 6025 Series of High Current Reversing Switches
        • DCCT Measurement Systems
          • Model 6300
        • Precision Shunts
          • 1A to 300A, 500 & 1000A, Multiple Current Shunts, AC Shunts
        • Smart Resistors
          • SmartResistor an Automated Resistance Standard
        • Multiple Current Shunts
          • Multiple Current Shunt – Temperature Stabilized
        • Multiple Resistance Standard
          • MHS
        • High Voltage Dividers
          • HVS High Voltage Standard
          • HVA High Voltage Divider
          • KV-A Precision High Voltage Dividers
          • KVVB 0.025 % Compact Divider
        • Standard Resistors
      • Voltage measurement
        • Voltage Dividers
          • Model 8001B 1200 V Extender
          • Model 8000B 10 V Binary Voltage Divider
        • Additional Divider Instrumentation
          • Model 8000B RVB (Ratio Verification Box)
          • Model 4240 Forty Channel Scanner
        • Automated Potentiometer Systems
          • Model 8000B/8001B Automated 1200 V Voltage Measurement System
      • Current Measurement
        • DCCT Calibration Systems – Model 6300
          • 6010 Systems Up To 3000A
          • DCCT Calibration Systems – Model 6300
        • High Current Resistance Measurement Systems
          • 6010 Systems Up To 3000A
    • Electrical Test Equipment
      • Transformer Loss Measurement System
        • Reactor Loss Measurement Systems
        • Model 2010A Wattmeter
      • Winding Resistance & Ratio Measurement System
        • Model AWRMS 50
        • Model AWRMS 200
        • PRT and MRT Range
        • SAPC & ART range
      • Power and energy calibration & Power Analyzers and Wattmeters
        • Model 2100A Power & Energy Calibration System
        • 2100B Power & Energy Calibration System
        • Model 2023A 3 Phase Power Analyzer
        • Model 2020A Power Analyzer
        • Model 2010A Wattmeter
      • Capacitance/ Inductance Tan Delta Bridge & Range Extenders & HV Standard capacitors
        • 7020 Two-Stage-Compensated Current Transformer
        • 7010C High Voltage, Capacitance, Inductance, Tan Delta Bridge
        • SPC range
        • AFP range
        • 12 kV or 15 kV AC Insulation Tests
        • 2 kV AC Insulation Tests
        • AC Dielectric Losses – All HV Tests
        • Dielectric Oils Tests
        • Solid Dielectric Insulant Tests
        • Tests of solid dielectric samples
        • HV 20kV to 50kV Portable Capacitors
        • High Capacitance plates Standard Capacitors 0.5 kV to 100 kV
        • 0.5 kV to 5 kV Reference Standard Capacitors, Medium Voltage
      • Current Transformers & Bushings with Voltage Dividers & Capacitors
        • Model 7021U Vertical Bushing
        • Model 7022U Vertical Bushing 6000A
        • Model 7023U Vertical Bushing
        • Model 7022U Vertical Bushing – 4000A
        • Model 7021/4000 Horizontal Bushing
        • Model 7021/2000 Horizontal Bushing
        • Model 7021/1000 Horizontal Bushing
        • Model 7020H Two-Stage-Compensated Current Transformer
        • 2503A High Voltage Divider
        • 2502A High Voltage Divider
        • 2501A High Voltage Divider
        • 2500A High Voltage Divider
      • High Voltage AC & DC Test Systems
      • Surge testers & Motor Heating protection test set
      • Digital Micro-ohmmeters
        • DMO200
        • DMO600
      • Relay Test Equipment
        • ART3V
        • 200ADM-P
      • Current Injection Test Sets
    • MI Calibration House
    • About
      • MILLP
      • Customers
      • Brands
    • Careers
    • Contact

    9316

    • Home
    • 9316
    6652A (1 MΩ to 100 TΩ) High Resistance Meter
    January 20, 2021
    9317
    June 20, 2019

    Datasheet
    Request a quote
     
     
    • Overview
    • High Stability
    • 1MΩ & 10MΩ/Step
    • Matched to <10ppm
    • Low Temperature Coefficient
    • Eliminates Oil/Air Bath Requirement

    The model 9316/9317 Resistor transfer standards consists of 11 equal steps of 1MΩ, (9316) and 10MΩ, (9317). Specially designed toggle switches isolate each resistor and allows the standard to be configured in series, parallel, series-parallel, or separately without the use of external shorting bars.

    Precise transfer measurements up to 110MΩ relative to a single 100kΩ resistance standard can be obtained with the MI 9317/9317 Resistance Transfer Standards. Based on a unique method for establishing known ratios, the 9316/9317 utilizes a transfer technique that consists of switching resistance elements in series, parallel or series-parallel selections.

    Insulation leakage paths (other than those within each resistance section) are from the external terminals to ground. By utilizing three-terminal measurement techniques insulation leakage errors in the transfer of calibration from one resistance level to another are minimized.

    Related posts

    June 20, 2019

    9317


    Read more
    June 20, 2019

    9331G


    Read more

    File name :DSC_0329.JPG File size :1.9MB(1982552Bytes) Date taken :2005/06/28 11:15:56 Image size :3008 x 1960 Resolution :300 x 300 dpi Number of bits :8bit/channel Protection attribute :Off Hide Attribute :Off Camera ID :N/A Camera :NIKON D1X Quality mode :FINE Metering mode :Matrix Exposure mode :Manual Speed light :Yes Focal length :70 mm Shutter speed :1/60second Aperture :F22.0 Exposure compensation:0 EV White Balance :Auto Lens :35 - 70 mm F 2.8 Flash sync mode :Normal Exposure difference :-8.4 EV Flexible program :No Sensitivity :ISO125 Sharpening :High Image Type :Color Color Mode :Mode II(Adobe RGB) Hue adjustment :3 Saturation Control :N/A Tone compensation :Normal Latitude(GPS) :N/A Longitude(GPS) :N/A Altitude(GPS) :N/A

    June 20, 2019

    9331 Series


    Read more

    About the company

    Measurements International has been extending the limits of electrical measurement performance for nearly 30 years. We can help you achieve the better measurement practices that your goals and quality systems need. Measurements International LLP (MILLP), India is the Indian arm of Measurements International and we at MILLP deal in the complete range of Test and Measuring Equipment and Calibration Standards (Transformers, Motors, Generator Testing, High Voltage, AC Power and DC Metrology, Electrical).

    Contact Us

    Measurements International LLP
    410, 4th Floor, KM, Trade Tower, Radisson Hotel Building, Sector -14, Kaushambi, Ghaziabad, Uttar Pradesh – 201010, India
    +91-120-2776277, +91-120-2642612
    sales@millp.co.in
    +91-120-4169460
    Follow us on Linkedin